50PTO 120/240V 1-PH 540RPM Generator

MSRP $7,310.00

Loading...

PTO Trailer* Optional

Clear selection
Subtotal:

Three Point Hitch* Optional

Clear selection
Subtotal:

PTO Shaft* Optional

Clear selection
Subtotal:
Product Base Price:
$7,310.00
Add-Ons Option Total:
Component Options Total:
Order Total:

The add to cart button is disabled because the following component is not selected:

Product Features

Starting at 50,000 standby watts, this 50PTO is single phase
with a 540RPM gearcase.
Rugged Design
     Our own WINCO gearcases have proven their strength
     and durability for over 60 years and will keep doing so
     into the future.
Low Harmonic Distortion
     Provides clean power for both farm and home.
Frequency Meter
      A large 3 1/2″ frequency meter ensures the proper output.
Premium Circuit Breakers
     Providing clear and instant identification of a tripped circuit.
Protective PTO Shield
     Safety is always a priority.
5-Wire Anderson Full Power Plug Included
100% Load Tested
     You won’t find statistical sampling here. We load test every
     generator before it leaves our facility.
WP DataTables

Additional Information

Standby Watts

50,000

Standby Amps

208 @ 1.0 PF

Continuous Watts

40,000

Continuous Amps

166 @ 1.0 PF

Voltage Output

120/240 Volt Single Phase

Voltage Regulation

AVR (Automatic Voltage Regulator)

120V Receptacles

(2) NEMA 5-20 20A

120/240 Anderson Connector

175 Amps

240V Receptacles

(1) NEMA 6-50R 50A

PTO Shaft

1 3/8" 6-spline
540 RPM

Dimensions

41" x 20" x 27"

Shipping Weight

680 lbs.

Unit Warranty

3 Years

Assembled In

USA

Share your thoughts!

Let us know what you think...

What others are saying

  1. Question

    Trey Beck

    Will my tractor run this generator. I have a Case 990 with 54 HP at the PTO.
    Thanks

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Josie Krugerud

      Josie Krugerud

      Hello Trey,

      In the PTO world, you will get roughly 1 kW per 2HP from the tractor’s PTO. Your tractor will definitely run the generator, but you will not get the full capacity. You will get about 27kW from your tractor. You will just have to make sure not to overload your tractor and cause it to stall. We do offer the 27PTO if you want to match your tractor’s kW potential. If you have more questions, you can always call us at 507-357-6821.

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  2. Question

    Morgan Wilson

    If I have a 150 hp tractor with a 1000 rpm pto, can I run a 540 adaptor and just run the engine fast enough to get 540? I’m thinking it would save some fuel and engine wear and tear if it wasn’t running at full rated and still would have enough power to spin the generator.

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  3. Question

    Oscar Coleman

    I have a MF 5445 with PTO rated 70-75 hp. Which of your generators would you match this with?

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Admin Josie Krugerud

      Hello Oscar, the rule of thumb is you need 2 HP for every 1kW. Your tractor can produce around 35 kW with this formula. We offer a 27PTO and a 50PTO. You can use your tractor with either one of these. You will only get out as much as the 27PTO produces, see spec sheet for output per your application. You will only get what the tractor can produce (35kW) from the 50PTO. If you have any further questions on sizing, please contact our sales department 507-357-6821.

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  4. Question

    Don Scott

    I have a 50kw pto generater 120/240 v it has a Anderson 4 wire cont.with cover do you sell this separate

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

×

Login

Continue as a Guest